Skip to content
Proudly Canadian. Serving Aurora and York Region. Get a free quote
(289) 513-7633

Orange and blue pipe east of Bayview Avenue: what to look for

Kitec was fitted in Ontario houses between 1995 and 2007, with a recall around 2005. The subdivisions east of Bayview Avenue in Aurora were built across exactly those years. This article explains which streets fall in the window, how to recognise the pipe, how it fails and how Plumbing Aurora replaces it without gutting the house.

Get a free quote

Optional, but it helps: we can confirm we serve your street and give you a realistic arrival time.

We reply by phone as soon as we can.

Key takeaways

  • Kitec's window takes in the later streets of Bayview Wellington, nearly the whole of Bayview Northeast and every street in Bayview Meadows.
  • Orange and blue pipe with brass stamped Kitec or KTC is the giveaway, and the mechanical room is the place to look.
  • Failure starts in the brass fittings, so replacement removes every one of them, in stages or in one planned job.

Why three Bayview neighbourhoods land in the window

Bayview Wellington began with Lester B. Pearson Public School in 1989 and Town Hall in 1991, and its townhomes, low-rise condos and starter homes filled in through the 1990s. The streets finished after 1995 are the candidates. Bayview Northeast grew from a 1996 secondary plan and an official plan amendment dated March 2000, so almost all of it was built inside the window. Bayview Meadows, the 210 acres along Spring Farm Road, was built from 2004 to 2009, straddling the recall itself. The census counts 18.3 per cent of the town's homes from the 1990s and 20.2 per cent from 2001 to 2010, so these are not a handful of houses.

Recognising the pipe and the KTC stamp

Go to the mechanical room and follow the lines leaving the water heater. Kitec is a flexible pipe with a layer of aluminum between two layers of plastic, orange on the hot side and blue on the cold. The giveaway is the brass at each joint, stamped Kitec or KTC. Check the manifold, the supply stubs to a basement bathroom and the tubing under the sinks. Insurers and buyers in these neighbourhoods ask about it as a matter of routine, so knowing the answer before you list or renew saves a scramble.

What a failing Kitec system looks like

The weak points are the brass fittings and the hot side of the pipe. The brass loses zinc over the years, and a white or greenish crust builds inside a fitting until flow drops or the joint weeps. Hot water speeds that along, so the first signs are often a shower that has lost pressure, a damp patch on the ceiling under a bathroom or a stain spreading from a fitting in the basement. A fitting can also let go behind drywall with no warning at all. Leaks in these houses are hidden ones, which is why the damage costs more than the pipe.

Replacing it in stages without gutting the house

Plumbing Aurora starts by tracing every run and listing which parts of the house are Kitec and which are copper or PEX, since a lot of these houses carry more than one pipe type. The first stage is the mechanical room and the basement ceiling. Each bathroom then follows as its own stage, with small openings at the valve and the vanity and the water back on by evening. Every brass fitting comes out, because new pipe on old brass leaves the problem in the wall. One planned job saves the repeated shut-downs, but a staged job gets the worst fittings out first.

Related services

  • Kitec Plumbing Replacement

    Need Kitec Plumbing Replacement in Aurora? Plumbing Aurora replaces Kitec lines and verifies tight, reliable service. Request a quote.

  • Leak Detection

    Need Leak Detection in Aurora? Plumbing Aurora locates leaks accurately and outlines repair choices. Book an assessment.

  • Repiping

    Need Repiping in Aurora? Plumbing Aurora upgrades old piping and confirms everything holds under pressure. Schedule a quote.

FAQ

Orange and blue pipe east of Bayview Avenue: what to look for questions

Is Kitec a sure thing in a 2005 Bayview Meadows house?
Not certain, but likely enough to check before anything else. The neighbourhood was built from 2004 to 2009, the years around the recall, so a 2005 build sits in the middle of the window. Builders did not all use the same pipe, so look at the fittings off the heater before assuming.
What does a failing Kitec fitting look like before it leaks?
A dull white or green crust on the brass, a pipe that feels stiff near the joint, and hot water pressure that has slipped over a year or two. On a finished ceiling the first sign is usually a tea-coloured stain under a bathroom. Any of those is reason to have the system traced.
Which rooms open up first in a staged Kitec job?
The mechanical room and the basement ceiling, because the most fittings sit there and the drywall, if there is any, is the cheapest to patch. Then the bathroom that gets the most use, with openings behind the shower valve and under the vanity. Kitchens usually come last since the runs there are short.

Read next

Urgent Plumbing Repair, Installation & Maintenance Services

Call now

Get a free quote

Optional, but it helps: we can confirm we serve your street and give you a realistic arrival time.

We reply by phone as soon as we can.

Search